Reference data for the design of tunnel type SiC furnace Description
element electric furnace (practice).*****
1. Material loaded on furnace cart: transformer power 500
KW/M3 is used for constant temperature (furnace chamber
volume).
Material loaded on pushing plate: transformer power 450
KW/M3 is used for (furnace chamber volume), max power
209KW/M3 is used for constant temperature (furnace chamber
volume).***
2. In each M3 of furnace chamber, the total area
for SiC element heating part that can be installed is:
material loaded on furnace cart, 46420cm2; on pushing
plate, 41777 cm2.***
3. The quantity of SiC heating element that should
be installed in the electric furnace used = total surface
area of the rod heat-generating part selected (cm2).***
Note: The above data are for the max temperature area. For
other temperature area data, please reference those for
batch-type furnace.***