Single Channel Gas Monitor Description
| Single Channel Gas Monitor(DS-3000)
Product Features - Digital Display - Fan/Alarm relay contact - Suitable for Underground Parking lots in PLC system - Available combustible gas, toxic gas
I. MONITORING PART Gas Sampling Mode : Diffusion Principle of Detection: Electro-Chemical Sensor Power Source : AC110/200V 50/60Hz Power Consumption : 7~12W Indication : FND Digital Display Detection Range : 0 ~ ppm, 0 ~ 100% available Detectable Gas : Toxic gas - CO, CO2, H2S, NH3..... Combustible gas- LNG, LPG, CH4.... Response Time : Within 20 seconds. Stabilizing time : About 1 minute. External Dimension : 187(L)mm x 212(W)mm x 108(H)mm Weight : About 1.5kg Application : Chemical & Petrochemical industry. Pulp, Paper, Semiconductor industry. Gas equipment industry etc. Operating Temperature : -20ĦE ~ +50ĦE Operating Humidity : 0 ~ 85% RH Alarm Mode : Buzzer sound and Red LED Lamp fickering Connecting Cable : VCT or CWS 0.75 ~ 2.0mm (2, 3 wires) Output Power : DC 24V/ 200mA, Relay Contact Relay contact : AC115V 3A, DC28V 3A II. GAS DETECTING PART Gas Sampling Mode : Diffusion Principle of Detection: Electro-Chemical Sensor Structure : Protection of Explosion and Pressure Power Source : DC 24V Output Signal : 4 ~ 20mA (DC 1~ 5V) External Dimension : 133mm(diameter) * 200(L)mm * 70(H)mm
|